Floor-Mounted DC Charger 60-400kW
Contact Us
The floor-mounted DC charger uses high-efficiency 30kW or 40kW constant-power charging modules and supports output voltages up to 1000V. Charging efficiency exceeds 96%, and the charger supports wall-side installation. It is suitable for public charging stations, highway parking areas, and other commercial charging applications.
- Protection Rating: IP55
- Operating Temperature: -30°C to +70°C (power derating above 55°C)
- Standby Power Consumption: ≤20W
- Zero-Power Standby: Supported
Technical Specifications
| Mechanical | Cooling System | Forced air cooling | Forced air cooling | Forced air cooling | Forced air cooling |
| Dimensions (W × D × H) | 750 × 600 × 1800 mm | 750 × 600 × 1800 mm | 800 × 800 × 2000 mm | 800 × 800 × 2000 mm | |
| AC Input | Rated Input Voltage | 380 Vac ± 20% | 380 Vac ± 20% | 380 Vac ± 20% | 380 Vac ± 20% |
| Grid Frequency | 45 ~ 65 Hz | 45 ~ 65 Hz | 45 ~ 65 Hz | 45 ~ 65 Hz | |
| Power Factor (PF) | ≥ 0.99 | ≥ 0.99 | ≥ 0.99 | ≥ 0.99 | |
| System Efficiency | ≥ 96% (At half load and above) | ≥ 96% (At half load and above) | ≥ 96% (At half load and above) | ≥ 96% (At half load and above) | |
| DC Output | Output Channels | Supports single/dual connector configurations | Supports single/dual connector configurations | Supports single/dual connector configurations | Supports single/dual connector configurations |
| Output Voltage | DC 150 ~ 1000 V | DC 150 ~ 1000 V | DC 150 ~ 1000 V | DC 150 ~ 1000 V | |
| Max. Current / Single Connector | 250 A | 250 A | 250 A | 300 A | |
| Max. Current / Total System | 500 A | 500 A | 500 A | 600 A | |
| Compliance | BMS Communication | Compatible with old and new standards, meeting the charging needs of old and new vehicle models | |||
| Protection | Operating Temperature | -30°C ~ +70°C (Derating above 55°C) | -30°C ~ +70°C (Derating above 55°C) | -30°C ~ +70°C (Derating above 55°C) | -30°C ~ +70°C (Derating above 55°C) |
| Protection Functions | Input over/under voltage protection, Output overvoltage protection, Output overcurrent protection, Short circuit protection, Battery reverse connection protection, Insulation monitoring protection, Door enclosure protection, BMS data anomaly protection, Emergency stop protection, Electromagnetic lock anomaly protection, Abnormal un-plugging protection, Lightning/Surge protection, Anti-tilt alarm protection (optional), Flooding/Water-immersion alarm protection (optional), etc. | ||||
| Dustproof Class | G3-level dust filter | G3-level dust filter | G3-level dust filter | G3-level dust filter | |
Application Cases
Jiangzhuanghu Charging Station, Beijing
480kW-640kW Split-Type Rectifier Cabinet
Shangsi Mining Heavy Truck Charging Station, Guangxi
320kW Outdoor Dual-Gun Integrated DC Charger
Dongtie Mine Site, Anshan, Liaoning
640kW Outdoor Four-Gun Integrated DC Charger